Compare Products
Hide
VS
Centralized modular core switch with large buffer and high-density ports in the 4-RU space, which is recommended for the data center gateway zone, MAN, and DCI
Hardware Specifications
System Specifications |
RG-S6930-2C |
|
Switching Capacity |
28.8 Tbps |
|
Packet Forwarding Rate |
5400 Mpps |
|
Port Specifications |
||
Ports |
100GE/200GE ports |
|
Expansion Module Slots |
Two, each slot supporting the line card with up to 72 x 100GE ports or 36 x 200GE ports |
|
Expansion Modules |
Four power module slots, supporting 2+2 redundancy Eight fan module slots, supporting 7+1 redundancy |
|
Management Ports |
One management port, one Console port, and one USB port |
|
Dimensions and Weight |
||
Dimensions (W × D × H) |
442 mm x 760 mm x 175 mm (17.40 in. x 29.92 in. x 6.89 in., 4 RU) |
|
Weight |
33.55 kg (73.97 lbs., including eight fan modules and four power supply modules) |
|
Power Supply and Consumption |
||
Input Voltage |
AC |
● Rated input voltage range: 100 V AC to 127 V AC (50 Hz to 60 Hz), rated input current: 12 A ● Rated input voltage range: 200 V AC to 240 V AC (50 Hz to 60 Hz), rated input current: 9.5 A ● Max input voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz) |
HVDC |
● Rated voltage: 240 V DC ● Rated input current: 8.5 A |
|
Maximum Power Consumption |
● Max: 2934 W ● Typical: 1338 W ● Static: 600 W |
|
Environment and Reliability |
||
Operating Temperature |
0ºC to 40ºC (32ºF to 104ºF) |
|
Storage Temperature |
–40ºC to +70ºC (–40ºF to +158ºF) |
|
Operating Humidity |
10% RH to 90% RH (non-condensing) |
|
Storage humidity |
5% RH to 95% RH (non-condensing) |
|
Working altitude |
Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) |
Software Specification
Software Specification |
RG-S6930-2C |
802.1Q VLAN |
4094 |
L2 Protocols |
IEEE802.3ad (Link Aggregation Control Protocol), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP Snooping, MLD Snooping, Jumbo Frame (9 KB), IEEE802.1ad (basic QinQ and *selective QinQ), and GVRP |
L3 Protocols (IPv4) |
BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM Routing, Policy-based Routing, Routing Policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP, and Any-RP |
Basic IPv6 Protocols |
Neighbor Discovery, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping/Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, IPv6 MIB support for SNMP, VRRP for IPv6, and IPv6 QoS |
IPv6 Features |
Static routing, ECMP, PBR, BGP4+, OSPFv3, IS-ISv6, RIPng, MLDv1/v2, PIM-SMv6, manual tunnel, *automatic tunnel, IPv4 over IPv6 tunnel, and * ISATAP tunnel |
Visualization |
gRPC sFlow and IPFIX sampling |
Data center features |
Reporting buffer usage, queue traffic statistics, and packet drop statistics through gRPC Hang prevention MMU Querying queue peak time Displaying packet drop caused by insufficient buffer Displaying the number of buffer alarms Real-time buffer monitoring Reading unicast packet drop caused by buffer congestion through MIB |
Multicast |
IGMP Proxy、IGMP v1, v2, v3、IGMP host behavior、Querier election、Membership query and response、Static multicast route、IGMP fast leave、IGMP filter、IGMP v1 and v2 snooping、IVGL mode、Querier、Source IP address check、MLD proxy、MLDv1, v2、MLD snooping、MSDP、PIM-DM、PIM-SM v6(PIM-SM v6/PIM-SSM v6)、PIM-SMv4(PIM-SM/PIM-SSM) |
ACL |
ACL80、Dual-stack support for ACL、ACL-based redirection、IPv6 ACL、Standard IP ACL、Extended IP ACL、Extended MAC ACL、Ingress/Egress ACLs、Time-based ACL、Global ACL、Resource sharing in the case of applying an ACL on different physical ports or SVIs、ACL counter、ACL counter only、ACL logging、ACL re-marking、IPv4/IPv6 user-defined function(UDF) ACL、Displaying ACL resource usage、Expert-level ACL |
QoS |
802.1p, DSCP, and ToS priority mapping ACL-based traffic classification Priority marking and remarking Queue scheduling mechanisms, including SP, WFQ, and SP+WFQ |
HA Design |
GR for RIP/OSPF/BGP, BFD, REUP dual-link fast switching, RLDP unidirectional link detection, 2+2 power redundancy, fan redundancy, and hot swapping for all line cards and power supply modules |
Security Features |
MACSec, Network foundation protection policy (NFPP), CPU Protection Policy (CPP), DDoS attack defense, unauthorized data packet detection, source IP spoofing prevention, IP scanning prevention, RADIUS/TACACS, IPv4/v6 packet filtering by basic ACL, extended ACL or VLAN-based ACL, plaintext-based and MD5 authentication for OSPF, RIPv2, and BGPv4 packets, uRPF, broadcast packet suppression, Telnet login and password mechanisms for restricted IP addresses |
Management Modes |
SNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, syslog, and SPAN/RSPAN/ERSPAN |
Other Protocols |
DHCP Client, DHCP Relay, DHCP Server, DNS Client, UDP Relay, ARP Proxy, and Syslog |
*MPLS |
MPLS L3VPN, SR, and SRv6 |
* indicates that the feature will be supported in the future.
Safety and Regulatory Compliance
Specification |
RG-S6930-2C |
Safety |
● GB 4943.1 |
Electromagnetic Compatibility (EMC) |
● GB/T 9254.1 |
Environment |
● 2011/65/EU EN 50581 ● 2012/19/EU EN 50419 ● (EC) No.1907/2006 ● GB/T 26572 |
*For more country-specific regulatory information and approvals, contact your local sales agency.
Take the following steps to configure an RG-S6930-2C switch:
Model |
Description |
RG-S6930-2C |
RG-S6930-2C chassis equipped with four RG-PA1600II-F power supply modules and eight M2EFAN II-F fan modules Two expansion slots, four power supply module slots, and eight fan module slots |
Model |
Description |
RG-PA1600II-F |
1600 W power supply module (AC and 240 V HVDC) |
Model |
Description |
M2EFAN II-F |
Fan module (port-side intake) |
Model |
Description |
M6900-36CQ18DC-CES |
36 x 100GE QSFP28 ports and 18 x 200GE QSFP56 ports |
M6900-72CQ-CES |
72 x 100GE QSFP28 ports |
Model |
Description |
200G-Q56-SR4-MM850 |
200G SR4 module, QSFP56 form factor, MPO-12 connector, 100 m (328.08 ft.) over OM4 MMF |
Model |
Description |
100G-QSFP-LR4-SM1310 |
100G LR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 10 km (32,808.40 ft.) over SMF |
100G-QSFP-iLR4-SM1310 |
100G iLR4 module, QSFP28 form factor, Duplex LC, 1310 nm, 2 km (6,561.68 ft.) over SMF |
100G-QSFP-SR-MM850 |
100G SR module, QSFP28 form factor, MPO, 850 nm, 100 m (328.08 ft.) over MMF |
100G-QSFP-ER4-SM1310 |
100G ER4 module, QSFP28 form factor, Duplex LC, 1310 nm, 40 km (131,233.59 ft.) over SMF |
100G-AOC-10M |
100G QSFP28 AOC cable, 10 m (32.81 ft.) |
100G-AOC-5M |
100G QSFP28 AOC cable, 5 m (16.40 ft.) |
Model |
Description |
40G-QSFP-iLR4-SM1310 |
40G iLR4 module, QSFP+ form factor, Duplex LC, 2 km (6,561.68 ft.) over SMF |
40G-QSFP-LR4-SM1310 |
40G LR4 module, QSFP+ form factor, Duplex LC, 10 km (32,808.40 ft.) over SMF |
40G-QSFP-LSR-MM850 |
40G LSR module, QSFP+ form factor, MPO, 400 m (1,312.34 ft.) over MMF |
40G-QSFP-SR-MM850 |
40G SR module, QSFP+ form factor, MPO, 150 m (492.13 ft.) over MMF |
40G-QSFP-LX4-SM1310 |
40G LX4 module, QSFP+ form factor, Duplex LC connector, 150 m (492.13 ft.) over OM3/OM4 MMF, or 2 km (6,561.68 ft.) over SMF |
40G-AOC-30M |
40G QSFP+ AOC cable, 30 m (98.43 ft.) |
40G-AOC-5M |
40G QSFP+ AOC cable, 5 m (16.40 ft.) |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contactez-nous
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey